Thermal Contact Resistance Testing Apparatus - Qinsun
Professional Testing Instruments Manufacturer
Ulusal danışmanlık hattı:+86 021-64208466

Thermal Contact Resistance Testing Apparatus

Thermal contact resistance tester evaluates welder gloves' protection.

WhatsApp: +86 13816217984

E-posta adresi:info@qinsun-lab.com

İçerik

Thermal contact resisting testing device is designed with the adoption of advance technology for testing the thermal contact resistance of welder’s gloves which are used for protecting hands and wrists in the operation  process of welding and other related work.
 image.png
Technical Parameters
1、Heating unit contact surface diameter:(25.2±0.05)mm;
2、Calorimeter test surface diameter:(25±0.05)mm;
3、Contact force: (49±0.5)N;
4、Timer: 0~99.99s,Accuracy: ±0.01s;
5、Contact speed:95.0±0.2)mm/s ;
6、Sample size:diameter 80mm;

Standards
 AQ 6103-2007 Protective gloves for welders. Appendix E Testing method for thermal contact resistance.

Features
1.The heating unit is able to withstand a temperature up to 500℃,and the temperature is controllable.
2. Specially customized calorimeter meets test precision requirements.
3. Digital display the heating unit temperature, calorimeter temperature, critical time;
4. Contact speed is adjustable.
 
 

Sorumluluktan vazgeçme: Yukarıdaki içerik yalnızca endüstri içindeki kişiler arasında referans ve iletişim amacıdır ve doğruluğunu veya eksiksizliğini garanti etmez. İlgili yasa ve düzenlemelere ve bu web sitesinin düzenlemelerine göre, ilgili ürünleri satın alan birimler veya bireyler geçerli nitelikler ve nitelik koşulları almalıdır.