ASTM D93 Fully Automatic Oil Analysis Equipment Closed cup Flash Point Tester - Qinsun
Professional Testing Instruments Manufacturer
Ulusal danışmanlık hattı:+86 021-64208466
Ürünler

ASTM D93 Fully Automatic Oil Analysis Equipment Closed cup Flash Point Tester

Detailed product descriptionName:Closed Cup Flash Point TesterStandard:ASTM D93.Oil Cup Inner D

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

İçerik

Detailed product description

Name:Closed Cup Flash Point TesterStandard:ASTM D93.
Oil Cup Inner Diameter:50.7mm~50.8mm.Oil Cup Depth:55.7mm~56.0mm
The Scribed Line Depth Of Capacity Of Testing Oil:33.9mm~34.3mm.Capacity Of Testing Oil::About 70ml
Thermometers:Scale 20°C~150°C, Division 1°C.Keywords:Oil Analysis Equipment
Highlight:

oil analysis equipment

oil analysis machine

Main Features 

1.It adopts LCD screen to display. Full English man-machine dialog interface. It can preset the parameters of expected flash point, sample mark number, atmospheric pressure, test date, etc. It has menu to prompt and input function of guide type.

2.It adopts simulation tracking display the function curve of temperature rising and test time. It has prompt functions of English mis-operation, test date and test time.

3.It is equipped with standard RS-323.485 computer port. The lower computer can save 100 groups of historical data. The test data can be saved for a long time, transmitted and modified if the instrument being connected with computer.

4.It can correct the influence of atmospheric pressure and calculate the correction automatically.

5. Differential detection. Automatically correct the systematic deviation.

6. Automatically open the lid, ignite, detect and print test data. The test arm lifting up and down automatically.

7. It adopts electric ignition to fire light the gas flame. It will light only need to press the button.

8. Humanized design, beautiful and safe. Easy to operate.

Product parameters

1 .Power supply:AC(220±10%)V,50Hz

2. Temperature measurement Range: room temperature~300°C

Repeatability:≤3°C

Reproducibility:≤6°C

Accuracy:0.1°C

3. Heating rate: Procedure A:(5~6)°C/mi

Procedure B:(1~1.6)°C/min

Automatic control and manually adjustable.

4.Stirring rate

(1) Procedure A: (90~120)RPM

(2) Procedure B: (250±10)RPM

Automatic control and manually adjustable.

5.Igniting mode: Electric ignition. Gas flame diameter:3.2mm~4.8mm

6.Working condition: ambient temperature:(10~40)°C

relative humidity:≤80%

7. Maximum power consumption 500W

8. Dimension 520mm×360mm×310mm

1Power supplyAC(220±10%)V, 50Hz.
2Flash point determinationRange: Ambient to 300℃.
Meet requirement of GB/T 261-2008
Meet requirement of GB/T 261-2008
Resulotion: 0.1℃
3Heating rateProcedure A: (5~6)℃/min
Procedure B: (1~1.5)℃/min
4Stirring rateProcedure A: (90~120)RPM,
Procedure B: (250±10)RPM
Automatic control and manually adjustable.
5Igniting mode

Igniting source: gas(or other civilian fuels)Electric ignition.

Gas flame diameter: 3.2mm~4.8mm

6Ambient temperature≤ 40℃
7Relative humidity≤ 80%
8Maximum power consumption500W
9Overall dimension410mm×360mm×310mm
 

Sorumluluktan vazgeçme: Yukarıdaki içerik yalnızca endüstri içindeki kişiler arasında referans ve iletişim amacıdır ve doğruluğunu veya eksiksizliğini garanti etmez. İlgili yasa ve düzenlemelere ve bu web sitesinin düzenlemelerine göre, ilgili ürünleri satın alan birimler veya bireyler geçerli nitelikler ve nitelik koşulları almalıdır.