Main PurposeIt is mainly used for the extremely high - temperature pre - treatment of safety helmets
WhatsApp: +86 13816217984
E-posta adresi:info@qinsun-lab.com
Main Purpose
It is mainly used for the extremely high - temperature pre - treatment of safety helmets.
Compliance Standard
GB/T2812-2019
Technical Parameters
1. Test chamber temperature: Room temperature - 200°C, with the standard operating temperature being 150±5°C. 2. Test time: 0 - 99 minutes, adjustable, with the standard being 60±2 minutes. 3. Number of test samples: 1 - 4 helmets. 4. Head mold temperature: 50°C±2°C. 5. Test head mold: Wall thickness > 1.5mm, size according to No.1 in GB2812, made of aluminum alloy with a hollow interior. 6. Temperature - measuring point of the head mold: The distance from the mid - point of the head mold is < 40mm. 7. Instrument dimensions: 870*710*1100mm
Sorumluluktan vazgeçme: Yukarıdaki içerik yalnızca endüstri içindeki kişiler arasında referans ve iletişim amacıdır ve doğruluğunu veya eksiksizliğini garanti etmez. İlgili yasa ve düzenlemelere ve bu web sitesinin düzenlemelerine göre, ilgili ürünleri satın alan birimler veya bireyler geçerli nitelikler ve nitelik koşulları almalıdır.