Photovoltaic module outdoor exposure test system

Purpose:Under standard test conditions (1000W.m-2,25℃ battery temperature, GBT6495.3 standard solar

WhatsApp: +86 13816217984

E-posta adresi:info@qinsun-lab.com

İçerik

Standard

  • IEC 61215: Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval
  • IEC 61730: Photovoltaic (PV) Module Safety Qualification
  • UL 61730: Safety Standard for Photovoltaic Modules
  • ISO 9060: Solar Energy – Classification of Pyranometers
  • CE Certification (Conformité Européenne)

Product Advantages

  1. Real-World Accelerated Aging
    • 10–15 Year Equivalence: Achieves IEC 61215 damp heat/UV exposure in 6 months.
    • Spectral Matching: AM1.5G filter for standardized terrestrial solar simulation.
  2. Multi-Environment Testing
    • -40°C to +85°C Chamber: Replicates desert heat to polar cold with ±1°C stability.
    • 95% RH Humidity Control: Tests PID resistance in tropical/marine environments.
  3. Energy Harvesting
    • Grid-Tied Design: Offsets 70% of power consumption via test module output.
    • MPPT Tracking: Optimizes energy extraction during standby periods.
  4. Smart Data Acquisition
    • 16-Channel Logging: I-V curves, EL imaging, and thermal mapping in real-time.
    • AI-Powered Diagnostics: Predicts degradation modes (delamination, hotspots) via ML.
  5. Safety First
    • Arc-Fault Detection: UL 1699B-compliant for DC side protection.
    • Emergency Shutoff: Dual redundant safety circuits with GPS-enabled alerts.

Product Features

  • Dual-Axis Tracker: ±60° tilt, ±180° azimuth for precise solar alignment.
  • 10” Sunlight-Readable HMI: Preloaded IEC/UL test sequences with customizable dwell times.
  • Remote Monitoring: 4G/LTE connectivity with SMS/email alerts.
  • Self-Cleaning System: Automated rain simulation for dust accumulation studies.
  • Modular Design: Expandable from 5 kW to 50 kW for pilot-scale testing.

Technical Parameters

ParameterSpecification
Solar Irradiance300–1,200 W/m² (AM1.5G filtered)
Temperature Range-40°C to +85°C (operational)
Temperature Deviation≤±1°C (at steady state)
Humidity Range10%–95% RH (non-condensing)
Chamber Volume2m × 3m × 2.5m (W×D×H, expandable)
Power Supply380V/415V 3-phase, 50/60Hz
Dimensions2,500mm (W) × 3,500mm (D) × 3,000mm (H)
Weight1,200 kg (net) / 1,800 kg (gross)

Accessories Included

  1. Testing Kit:
    • 4x IEC 60904-4 compliant reference cells.
    • 10x Type T thermocouples with ceramic insulation.
  2. Software Suite:
    • License key for SolarTest Pro (Windows/Linux).
    • 1-year free access to cloud-based PV simulation tools.
  3. Calibration & Safety:
    • NIST-traceable irradiance meter.
    • Arc-flash protective gear (Class 2, 3 pairs).
  4. Maintenance Kit:
    • Spare fuses and surge protectors.
    • Chamber cleaning solution (non-corrosive).
  5. Documentation:
    • Multilingual quick-start guide (printed + digital).
    • Compliance certificates for IEC/UL/ISO standards
 

Sorumluluktan vazgeçme: Yukarıdaki içerik yalnızca endüstri içindeki kişiler arasında referans ve iletişim amacıdır ve doğruluğunu veya eksiksizliğini garanti etmez. İlgili yasa ve düzenlemelere ve bu web sitesinin düzenlemelerine göre, ilgili ürünleri satın alan birimler veya bireyler geçerli nitelikler ve nitelik koşulları almalıdır.


Çevrimiçi Mesaj

Kontakt detayları

Şirket Telefonu

+86-21-6420 0566

Çalışma saatleri

Pazartesi - Cuma

Cep telefonu:

13816217984

E-posta adresi:

info@qinsun-lab.com

QR Kodu