Contact heat transmission test machine - Qinsun
Professional Testing Instruments Manufacturer
Ulusal danışmanlık hattı:+86 021-64208466
Ürünler

Contact heat transmission test machine

Introduction:This part of ISO 12127 specifies a test method designed to evaluate the heat trans

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

İçerik

Introduction:

This part of ISO 12127 specifies a test method designed to evaluate the heat transfer and the behaviour of materials used for protective clothing when such materials are struck by high temperature metal particles, especially when these are trapped in the folds of the garment in working saituations.

Standard:

ISO12127-2

Technical Parameters

1. The equipment consists of Heating oven, control cabinet and stainless steel test bench.

2. The falling of steel cylinder, is controlled by motor and slide plate is controlled automatically, so that the steel cylinder falls automatically.

3. K type thermocouple with a diameter of 1.5mm and a temperature measurement of 0.1 ºC.

4. The Muffle furnace is used in the heating oven to control the heating temperature above 800 ºC.

5. Before the test, the temperature of calorimeter should be reduced to (20 ± 1) ºC.

6. Equipped with two weights, the weight is (175 ± 5) g.

7. The timing range of the timer is 0- 9999s, and the timing accuracy is 0.1s.

8. The dimensions of the copper disc are: diameter (8 ± 0.02) mm and the thickness (1.7 ± 0.02) mm.Comprising a K-type thermocouple inserted into the copper disc. Testing range≥1000ºC

9. Support block for the specimen and calorimeter , made of a curved aluminium sheet and fitted on a plastic base element.

10. Steel cylinder: Diameter: Ø 6.0 mm ± 11 µm ,Height: 12 mm ± 11 µm,Mass: 2.6 g ± 20 mg.

11. Sample diameter: (180*25)mm.

12. PLC and touch screen control system.

13. PID intelligent control, the system automatically collects temperature data (including start temperature, maximum temperature, temperature difference △ T, real-time temperature).

14. The test data is calculated and stored automatically/

15. Dimension:1800mm x 600 mm x 800mm.

16. AC 220V 50/60Hz, 6000W.

17. Manual and certificate of quality are provided.

Sorumluluktan vazgeçme: Yukarıdaki içerik yalnızca endüstri içindeki kişiler arasında referans ve iletişim amacıdır ve doğruluğunu veya eksiksizliğini garanti etmez. İlgili yasa ve düzenlemelere ve bu web sitesinin düzenlemelerine göre, ilgili ürünleri satın alan birimler veya bireyler geçerli nitelikler ve nitelik koşulları almalıdır.

Önceki:Flammability Tester STD-CFR 1610
sonraki:Gitti

Çevrimiçi Mesaj

Kontakt detayları

Şirket Telefonu

+86-21-6420 0566

Çalışma saatleri

Pazartesi - Cuma

Cep telefonu:

13816217984

E-posta adresi:

info@qinsun-lab.com

QR Kodu