Medical Masks bacterial filtration efficiency tester

Medical Masks bacterial filtration efficiency tester also called BFE test machine is to determine th

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Content

Medical Masks bacterial filtration efficiency tester also called BFE test machine is to determine the bacterial filtration efficiency (BFE) of medical face mask materials by employing a ratio of the upstream bacterial challenge to downstream residual concentration of the tested medical face mask materials.

Application

This machine is suitable for metrological verification departments, scientific research institutes, mask manufacturers and other relevant departments to measure the bacterial filtration efficiency (BFE) of medical face mask materials.

Standards

YY 0469-2004 Technical requirements for surgical mask

BS EN 14683-2014 Medical face masks - Requirements and test methods

ASTM F2100-2019 Standard Specification for Performance of Materials Used in Medical Face Masks

ASTM F2101 Standard Test Method for Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials, Using a Biological Aerosol of Staphylococcus aureus

Feature

1. Professional negative pressure biological safety cabinet technology to ensure the safety of operators and the environment.

2. High negative pressure working cabin, two-stage high-efficiency filter, 100% safe discharge.

3. Adopt two-way six-level Anderson precise sampling.

4. Built-in peristaltic pump with adjustable flow rate.

5. Special microbial aerosol generator, the flow rate of bacterial liquid spray is adjustable, and the atomization effect is good.

6. Industrial-grade large color touch screen control, the operation is simpler.

7. The control system adopts PLC + LabView control, high-intensity color touch screen 10 inches, USB interface, supports U disk data transfer;.

8. The safety cabinet has built-in LED lighting for easy observation.

9. Built-in ultraviolet disinfection lamp to enhance the protection effect.

10. The front switch type sealed glass door is convenient for operation and observation.

11. With operating software, it can be controlled and processed by computer.

12. Seamlessly connect the laboratory information management system.

Parameters

Sampling flow rate of Path A

28.3L/min

Sampling flow rate of Path B

28.3L/min

Nebulization flow rate

(8~10)L/min

Peristaltic pump flow rate

0.006~3mL/min

Negative pressure of aerosol chamber

-90~-120Pa

Negative pressure of cabinet body

(-50~-200)Pa    

Andersen

I>7μm, II. 4.7-7μm, III. 3.3-4.7μm, IV. 2.1-3.3μm, V. 1.1-2.1μm

VI. 0.6-1.1μm

Size of glass aerosol chamber

L600×diameter85Xthick3)mm

Outer Dimension

1180*650*1300cm(L*W*H)mm

     Power supply

220V 50Hz

Accessoriess

The accessories for a medical mask bacterial filtration efficiency tester mainly include the following categories, with a brief description of their functions:

Aerosol Generation System Accessories: Includes a peristaltic pump, aerosol generator, compressed air, and purification device, used to generate stable bacterial aerosols.

Aerosol Chamber and Transmission Device Accessories: Composed of an aerosol chamber, high-efficiency air filter, and negative pressure exhaust fan, used to contain aerosols and transmit them to the sampler.

Sampling System Accessories: Employs a dual-path, six-stage Anderson sampler, with a sampling flow rate of 28.3 L/min per path, used to capture particles of different sizes.

Negative Pressure Cabinet Accessories: Contains a peristaltic pump, lighting, and leakage protection switch, ensuring operational safety and maintaining a stable negative pressure environment.

Control and Display Accessories: Equipped with an embedded high-speed industrial microcomputer and a 10.4-inch color touchscreen display, enabling automated control and real-time data monitoring.

Auxiliary accessories include a USB interface (supporting data transfer), dual-purpose casters for easy movement of the equipment, and a front-mounted switchable glass door (for easy observation and operation).

Test Procedures

(1) Mount the pretreated mask sample onto the test fixture.

(2) Start the aerosol generator to produce a stable aerosol.

(3) Collect upstream and downstream samples simultaneously.

(4) Incubate the collected samples at 37°C for 48 hours.

(5) Count the colony-forming units (CFU).

YouTube video introduction:https://www.youtube.com/watch?v=i0EM6Zr9hxk

Qinsun Instruments Co., LTD is a professional laboratory testing instrument manufacturer in China,Have been focusing on laboratory instrument R&D more than 30 years and have rich industry experience,Based on international testing standards,We are also the instrument supplier for BV SGS laboratory,We provide one-stop solutions for lab instruments,Free Training and Turn-Key Service,Products exported all over the world,Offer 36 month warranty and are a trustworthy partner.


Online Message

Contact Details

Company Phone

+86-21-6420 0566

Working hours

Monday to Friday

Mobile phone:

13816217984

Email:

info@qinsun-lab.com

QR code